AC High Voltage Test Sets for GIS
● Transformer
● GIS system
● SF6 switchgear
● Cables
● Bushing
● Insulator
● CT/PT
● Other capacitive devices
● Small temperature rises at rated load. Dry or Oil type reactors, high mechanical strength, good insulation, nice and reliable.
● Adjustable capacity of frequency control source. Strong protection, good stability. With multiple working mode, easy to operate.
● With 220V or 380V single phase power, convenient for on-site power sourcing.
● Flexible configuration. Different type reactors for optional, meet different test object requirements. Multifunctional, cost effective.
● Rated output voltage: based on different test objects.
● Output frequency: 20- 300Hz.
● Waveform: pure sine wave, THD <1.0%.
● Max. capacity: 1000kVA and below.
● Duty Cycle: Continuous working time 15mins one time at full power output. (or customer demand.)
● Frequency adjustment sensitivity: 0.1Hz, instability <0.05%.
● Power Supply: 380/220V ± 15%/50Hz ± 5%.
| GDTF-108/108 | |
| Input voltage (V) | 380 | 
| Output voltage (kV) | 0-108 | 
| Capacity (kVA) | 108 | 
| Application scope | 31500kVA or below | 
| 35kV power transformer | |
| 35kV circuit breaker and bus bar, insulators | |
| 10kV (300 mm²) cable 2000m | |
| 35k V (300 mm²)cable 500m | |
| Main configurations | 5kW Variable frequency source 1 set | 
| 5kVA Exciting transformer 1 set | |
| Reactors 27kV/1A 4sets | |
| Capacitive divider 100kV | |
| GDTF-216/216 | |
| Input voltage (V) | 380 | 
| Output voltage (kV) | 0-216 | 
| Capacity (kVA) | 216 | 
| Application scope | 110kV Circuit breaker and bus bar | 
| 110kV GIS | |
| 35kV(300 mm²) cable 1500m | |
| 10kV(300 mm²) cable 3km | |
| 110kV full insulation Transformer | |
| Main configurations | 10kW Variable frequency source 1 set | 
| 10kVA Exciting transformer 1 set | |
| Reactors 54kV/1A 4sets | |
| Capacitive divider 200kV | |
| GDTF-270/270 | |
| Input voltage (V) | 380 | 
| Output voltage (kV) | 0-270 | 
| Capacity (kVA) | 270 | 
| Application scope | 110kV GIS and transformer | 
| 110kV GIS and transformer | |
| 35kV (300 mm²) cable 2km | |
| Main configurations | 15kW Variable frequency source 1 set | 
| 15kVA Exciting transformer 1 set | |
| Reactors 54kV/1A 5sets | |
| Capacitive divider 300kV | |
| GDTF-400/400 | |
| Input voltage (V) | 380 | 
| Output voltage (kV) | 0-400 | 
| Capacity (kVA) | 400 | 
| Application scope | 220kV GIS and transformer | 
| 10kV (300 mm²) cable 4km | |
| 35kV (300 mm²) cable 1km | |
| Main configurations | 20kW Variable frequency source 1 set | 
| 20kVA Exciting transformer 1 set | |
| Reactor  | |
| Capacitive divider 400kV | |
| GDTF-520/260 | |
| Input voltage (V) | 380 | 
| Output voltage (kV) | 0-260 | 
| Capacity (kVA) | 520 | 
| Application scope | 110KV Circuit breaker and bus bar | 
| 110kV GIS | |
| 110kV (300 mm²) cable 800m | |
| 35kv (300 mm²) cable 3km | |
| 10kV (300 mm²) cable 6km | |
| 110kv full insulation Transformer | |
| Main configurations | 25kW Variable frequency source 1 set | 
| 25kVA Exciting transformer 1 set | |
| Reactor 65kV/2A 4sets | |
| Capacitive divider 300kV | |
| GDTF-500/500 | |
| Input voltage (V) | 380 | 
| Output voltage (kV) | 0-500 | 
| Capacity (kVA) | 500 | 
| Application scope | 220kV or below CT/PT | 
| 220kV or below bushing | |
| 220kV or below Insulators, disconnectors | |
| 220kV or below Circuit breaker | |
| 220kV or below Insulation Instrument | |
| Main configurations | 20kW Variable frequency source 1 set | 
| 20kVA Exciting transformer 1 set | |
| Reactor 125kV/1A 4sets | |
| Capacitive divider 500kV | |
| GDTF-600/600 | |
| Input voltage (V) | 380 | 
| Output voltage (kV) | 0-600 | 
| Capacity (kVA) | 600 | 
| Application scope | 110kV (300 mm²) cable 800m | 
| 35kv (300 mm²) cable 110m | |
| 35-220kV GIS, transformers, insulators | |
| Main configurations | 30kW Variable frequency source 1 set | 
| 30kVA Exciting transformer 1 set | |
| Reactor 120kV/1A 5sets | |
| Capacitive divider 600kV | |
| GDTF-800/800 | |
| Input voltage (V) | 380 | 
| Output voltage (kV) | 0-800 | 
| Capacity (kVA) | 800 | 
| Application scope | 110kV (300 mm²) cable 800m | 
| 220kv (300 mm²) cable 500m | |
| 35-500kV GIS, transformers, insulators | |
| Main configurations | 40kW Variable frequency source 1 set | 
| 40kVA Exciting transformer 1 set | |
| Reactor 200kV/1A 4sets | |
| Capacitive divider 800kV | |
 
				        










