Technical Guide

Technical Guide

  • Exploring SF6/N2 mixed gas : advantages, applications, and analysis

    Exploring SF6/N2 mixed gas : advantages, applications, and analysis

    SF6/N2 mixed gas is a widely used insulation medium in the power industry. In traditional GIS (gas insulated switchgear), SF6 gas has always been used as an insulation medium, but due to its high global warming potential, SF6 is gradually receiving attention. In contrast, SF6/N2 gas mixtures have...
    Read more
  • What causes the current transformer to burn out

    What causes the current transformer to burn out

       HV HIPOT GDHG-306D  CT/PT Analyzer The first reason is that the secondary side of the current transformer is caused by an open circuit due to weak wiring In the process of using a current transformer, if the secondary side opens due to wire disconnection, the current will be equal to ze...
    Read more
  • HV HIPOT SF6 N2 Mixed Gas Purity Analyzer

    HV HIPOT SF6 N2 Mixed Gas Purity Analyzer

    Technical characteristics: 1. Fully imported high-precision sensors with self calibration function ensure stable and reliable purity detection data throughout the year. 2. Used for high-precision testing of SF6 gas purity value and N2/CF4 ratio value, and can also analyze the O2 content in the ...
    Read more
  • Problems encountered in maintenance and testing of loop resistance tester

    Problems encountered in maintenance and testing of loop resistance tester

    The loop resistance tester is widely used in the measurement of contact resistance, loop resistance, cable and wire, weld contact resistance of various domestic electrical control switches in enterprises. Our company R & D and production of high-precision loop resistance tester, accurate meas...
    Read more
  • How to test whether the motor winding is grounded

    How to test whether the motor winding is grounded

    When the windings of the motor short circuit to the ground, short circuit to each other or open the circuit (that is, the winding wire breaks), the motor will fail. The wires in the winding use an insulating covering as an isolation barrier. If the insulation layer of the winding is worn near the...
    Read more
  • What are the measurement methods of using a high voltage generator

    What are the measurement methods of using a high voltage generator

    High voltage generator alias direct high voltage generator or DC high voltage generator, it is specially used to detect the electrical insulation strength and leakage current of power devices. Generally, the use of high voltage generators is to carry out DC voltage withstand test on zinc oxide ar...
    Read more
  • Ground fault Circuit breaker test troubleshooting

    Ground fault Circuit breaker test troubleshooting

    Troubleshooting ground fault circuit interrupts or GFI breakers is simple. Troubleshooting the circuit itself can be time-consuming. The GFI circuit breaker design has a test button integrated into the circuit breaker itself. Pressing the test button should trip the circuit breaker. On a GFI type...
    Read more
  • Causes of partial discharge of high voltage switchgear

    Causes of partial discharge of high voltage switchgear

    During the operation of power equipment, when partial discharge occurs, various charged particles such as electrons, positive and negative ions, stimulated by the electric field, generally have more energy than the bond energy of the polymer. These charged particles strike the walls of the dielec...
    Read more
  • Problems encountered in maintenance and testing of loop resistance tester

    Problems encountered in maintenance and testing of loop resistance tester

    Loop resistance testers are widely used in enterprises to measure the contact resistance, loop resistance, cable wires, and weld contact resistance of various household electrical appliance control switches. The high-precision loop resistance tester developed and produced by our company has accur...
    Read more
  • Daily maintenance of cable fault locator

    Daily maintenance of cable fault locator

    1. Load monitoring Monitoring cable load can help us understand the changes in cable load and analyze the way the cable works. Since overload can seriously damage the cable, the load on the cable should be measured and monitored regularly. Clip-on ammeters can be used to measure the load on cable...
    Read more
  • The necessity and function analysis of SVG in photovoltaic power station

    The necessity and function analysis of SVG in photovoltaic power station

    With the enhancement of global environmental awareness and the rapid development of renewable energy, photovoltaic power generation has gradually entered people’s lives as a clean energy. However, in the operation of photovoltaic power plants, power quality problems have become increasingly...
    Read more
  • Steps for Cable Fault Locating

    Steps for Cable Fault Locating

      1. Between the determination of cable fault, the tester must first determine the nature of the cable fault in addition to mastering the performance and operation methods of the machine, so as to adopt appropriate working methods and test methods. First, use a megohm meter or multimeter to measu...
    Read more